    Spraying Technology of Iron Tower

    author:Bohai Steel Structure Co., Ltd.

    【Font size: big medium smail

    time:2019-10-08 12:30:07

    铁塔 喷塑 工艺

    Steel structure has been widely used in light weight, high strength, high degree of industrialization, good seismic performance, fast construction speed and recyclable buildings, large-span buildings and high-rise buildings. However, it is also because of the high material strength of steel structure, the relatively small section of steel structure members, steel structure members often show the characteristics of long, thin, flexible, thin and so on. In order to save steel consumption, the "stress ratio" of steel structure to section strength is generally larger in design. Therefore, the sensitivity of steel structure to geometric deviation, local stress and corrosion in processing and installation is stronger than that of vehicle. Therefore, it is very important to strengthen the control of construction quality of steel structure engineering to ensure that the steel structure engineering achieves the anticipated goal. There is no scene sound and evaluation in the case of deviation in processing and installation. There is no corresponding understanding of the influence of various defects that may appear in the construction process on the joint performance. It may result in improper handling of quality problems such as errors in the process of processing and installation of steel structures in practical projects, which will cause great waste or become a potential safety hazard.

    Therefore, although strengthening the construction quality control of steel structure engineering, it is very important to understand all kinds of quality problems and defects for the influence of structural performance. 1. The classification of processing and installation deviation in acceptance code 1.1. The deviation related to single-storey frame structure is based on the construction acceptance regulations [1], steel structure engineering in processing and installation. Various deviations that may occur during the loading process are distinguished according to single-layer and multi-layer. This paper classifies the deviation of direct scene noise of structural performance [2], in order to understand all kinds of deviation 1). The allowable deviation of single-layer steel structure column installation in acceptance code is the deviation of the center line of column base positioning axis. See Fig. 1, the allowable deviation A is 5 mm, Fig. 1, the deviation diagram of single-layer column base. The prescribed limit is inconsistent with the allowable deviation diaphragm of the steel column foot bolt, because the allowable deviation of the foot bolt in GB50205 is 5 mm and the center deviation of the reserved hole is 10 mm.

    In the acceptance code, the deviation of the bending vector height for the installation of single-storey steel columns shall not exceed the deviation H/1200 (mm) (H is the height of single-storey steel columns) and the deviation 3 for the vertical axis of single-storey steel columns shall be the deviation gauge for the acceptance code. For single-storey columns: H < 10m, the axis perpendicularity of single-storey steel structure column is allowed to deviate lH/1000 (mm) (H is the height of single-storey steel structure column); when H > 10m, the axis perpendicularity allowable deviation of single-storey steel structure column is similar to that of multi-section columns. Figure 2, axis perpendicularity deviation of single-storey column. Figure 4) The deviation of single-storey steel structure is in the acceptance code, and for beam members. The allowable deviation of the lateral angular bending vector height (30m for the rhythm of single-layer steel beam, 100mm for the allowable deviation), should not be greater than 10mm 60m, 1000mm for the allowable deviation, and should not be greater than 30mm1 > 60m for the allowable deviation, and / 1000 (mm for the allowable deviation).

    Reprint please indicate:http://www.63beds.com/ttps-1061.html
    国国内清清草原免费视频